Difference between revisions of "INHIBIT LOGINS?"
From VistApedia
DavidWhitten (talk | contribs) (Created page with " When running ^XUS or initially connecting to your VistA system, you might see this message: Signons not currently allowed on this processor. This message occurs because th...") |
DavidWhitten (talk | contribs) |
||
Line 3: | Line 3: | ||
When running ^XUS or initially connecting to your VistA system, you might see this message: | When running ^XUS or initially connecting to your VistA system, you might see this message: | ||
− | Signons not currently allowed on this processor. | + | <b> Signons not currently allowed on this processor. </b> |
+ | |||
+ | Alternately, you might see the message: | ||
+ | |||
+ | <b> Sorry, all activity on this volume set is being halted! Try again later </b> | ||
+ | |||
This message occurs because the VOLUME SET entry has a field INHIBIT LOGINS? that has been set to | This message occurs because the VOLUME SET entry has a field INHIBIT LOGINS? that has been set to |
Revision as of 17:09, 26 June 2014
When running ^XUS or initially connecting to your VistA system, you might see this message:
Signons not currently allowed on this processor.
Alternately, you might see the message:
Sorry, all activity on this volume set is being halted! Try again later
This message occurs because the VOLUME SET entry has a field INHIBIT LOGINS? that has been set to
MUMPS>DO P^DI VA FileMan 22.0 Select OPTION: INQUIRE TO FILE ENTRIES OUTPUT FROM WHAT FILE: VOLUME SET// Select VOLUME SET: `1 EHR ANOTHER ONE: STANDARD CAPTIONED OUTPUT? Yes// (Yes) Include COMPUTED fields: (N/Y/R/B): NO// BOTH Computed Fields and Record Number (IEN) NUMBER: 1 VOLUME SET: EHR INHIBIT LOGONS?: YES OUT OF SERVICE?: NO REQUIRED VOLUME SET?: NO TASKMAN FILES UCI: EHR TASKMAN FILES VOLUME SET: EHR DAYS TO KEEP OLD TASKS: 0 TYPE: GENERAL PURPOSE VOLUME SET SIGNON/PRODUCTION VOLUME SET: Yes
Select OPTION: ENTER OR EDIT FILE ENTRIES INPUT TO WHAT FILE: KERNEL SYSTEM PARAMETERS// VOLUME SET (1 entry) EDIT WHICH FIELD: ALL// Select VOLUME SET: `1 EHR VOLUME SET: EHR// TYPE: GENERAL PURPOSE VOLUME SET// INHIBIT LOGONS?: YES// ? Choose from: Y YES N NO S SYSTEM SHUTDOWN INHIBIT LOGONS?: YES//NO LINK ACCESS?: ^