If you get a message like

"Sorry, all activity on this volume set is being halted!  Try again later."

then you probably have had the flag for disabling logins set.

This flag is part of the patch process, and is part of the system management for a VistA system. Usually, a system manager has access to the system using programming mode, so it doesn't keep them from performing their work.

To change this flag, the following dialog may be helpful, specifically the line marked in RED : In this example the field's value is NO, but the message typically occurs when the value is YES. It can be changed simply by typing NO when prompted.

MUMPS>d Q^DI
 
VA FileMan 22.0
 
Select OPTION: 1  ENTER OR EDIT FILE ENTRIES
 
INPUT TO WHAT FILE: VOLUME SET// volume set    (1 entry)
EDIT WHICH FIELD: ALL//
 
Select VOLUME SET: EHR
VOLUME SET: EHR//
TYPE: GENERAL PURPOSE VOLUME SET//
INHIBIT LOGONS?: NO//
LINK ACCESS?: YES//
OUT OF SERVICE?: NO//
REQUIRED VOLUME SET?: NO//
TASKMAN FILES UCI: EHR//
TASKMAN FILES VOLUME SET: EHR//
REPLACEMENT VOLUME SET:
DAYS TO KEEP OLD TASKS: 4//
SIGNON/PRODUCTION VOLUME SET: Yes//