RPC HELP Tutorial Step 5
Tutorial: Step 5 -- RPC to List Terminal Types
Now that you've created an RPC-compatible routine to list terminal types (Step 4), you can go ahead and create the RPC itself (the entry in the REMOTE PROCEDURE file) that will call the routine.
To create an RPC that uses the TERMLIST^ZxxxTT routine:
Using VA FileMan, create a new RPC entry in the REMOTE PROCEDURE file. Set up the RPC as follows:
NAME: ZxxxTT LIST TAG: TERMLIST ROUTINE: ZxxxTT RETURN VALUE TYPE: GLOBAL ARRAY WORD WRAP ON: TRUE DESCRIPTION: Used in RPC Broker developer tutorial.
The RPC's RETURN VALUE TYPE is set to GLOBAL ARRAY. This means that the RPC expects a return value that is a global reference (with data stored at that global reference). Also, the RPC's WORD WRAP ON is set to TRUE. This means each data node from the VistA M Server is returned as a single node in the Results property of your TRPCBroker component in Delphi. Otherwise, the data would be returned concatenated into a single node in the Results property.
In the next step of the tutorial (Step 6) you will call this RPC from the tutorial application, through its TRPCBroker component.